R-410A vs R-22: Which Refrigerant Does Your Air Conditioner Use?
Most central air conditioners and heat pumps in American homes run on one of two refrigerants: R-22, in older equipment, or R-410A, in most systems installed from about 2010 onward. They look alike on a spec sheet and they do the same job, but they are not interchangeable. Here is how to tell which one you have and what that means for service.
How to tell which refrigerant your system uses
Look at the data plate on the outdoor unit. It lists the refrigerant by name and the factory charge in pounds and ounces. The indoor coil usually carries a matching label. If the plate is missing or unreadable, the age of the equipment is a strong clue: under EPA rules, new air conditioners and heat pumps charged with R-22 could not be manufactured from January 1, 2010, so a system built before then is very likely R-22.
Do not go by cylinder colour. Read the label on the cylinder and on the equipment.
The differences that matter
| R-22 | R-410A | |
|---|---|---|
| Type | HCFC (contains chlorine) | HFC blend |
| Ozone layer | Ozone-depleting | Not ozone-depleting |
| Operating pressure | Lower | Much higher; components are rated for it |
| Compressor oil | Mineral or alkylbenzene oil | POE (polyolester) oil |
| Supply | U.S. production and import ended January 1, 2020; service uses reclaimed and previously produced gas | Still produced, but HFCs are being phased down; new home AC equipment has moved to lower-GWP refrigerants such as R-454B and R-32 |
Can you put R-410A in an R-22 system?
No. R-410A runs at far higher pressures than an R-22 system is built for, and it needs a different oil. Mixing two refrigerants is just as bad: the result has the published properties of neither gas, so no pressure–temperature chart describes it and no gauge reading means anything. A system that has been charged with the wrong refrigerant, or a mix, has to be recovered and recharged, not topped up.
Servicing an R-22 system today
The EPA does not require anyone to replace a working R-22 system, and it can still be repaired. Because no new R-22 is made or imported, service relies on reclaimed and previously produced R-22, and that supply shrinks over time. The other route is an R-22 replacement blend such as R-421A, R-422B, R-422D or R-438A. These are not identical to R-22: capacity, oil compatibility and the retrofit procedure differ from one blend to the next, so follow the blend manufacturer’s guidance and the equipment maker’s recommendations before converting a system.
When a system needs a major repair, such as a compressor or a coil, it is worth comparing that cost with replacing the equipment with a current-generation system.
Who can buy R-22 and R-410A
Both are restricted under EPA Section 608. They may only be sold to certified technicians and the other buyers the regulation allows. Our refrigerant compliance policy explains who qualifies and what ordering confirms.